KjConditionTransplantsAndOtherForeignBodies profile

The KjConditionTransplantsAndOtherForeignBodies profile is used for registration of transplants and other foreign objects in the body the patient has. Use for non-mechanical implants (transplants), e.g. 'Transplantert nyre'.

Profile elements

https://simplifier.net/kjernejournalr4/kjconditiontransplantsandotherforeignbodies

Element Description Comment
id Record id id + meta.versionId is the unique identifier
meta.versionId Record version id
clinicalStatus active | inactive
verificationStatus confirmed | refuted | entered-in-error
category Type of critical information
category.coding Category coding for transplants and other foreign bodies
code Identification of the condition, problem or diagnosis
code.coding Coding for transplants and other foreign bodies
code.text Text if no proper code is found
subject Who has the condition
onset Estimated or actual date, date-time, or age
recordedDate Date record was first recorded
recorder Who recorded this condition first Use contained reference
note Note
extension.sourceOfInformation Source of information
extension.updater Who changed this version of the resource Use contained reference
extension.updatedDateTime When this version of the resource was changed
extension.validUntil Optional valid until date The registration may be displayed as inactive if its valid-until date has expired

Example

{
  "resourceType": "Condition",
  "id": "adee3a5a-61a0-4cec-bfb2-6fad3df552de",
  "meta": {
    "versionId": "1",
    "lastUpdated": "2024-04-22T12:58:40.415+00:00",
    "profile": [
      "http://nhn.no/kj/fhir/StructureDefinition/KjConditionTransplantsAndOtherForeignBodies"
    ]
  },
  "contained": [
    {
      "resourceType": "PractitionerRole",
      "id": "recorderRef",
      "practitioner": {
        "identifier": {
          "system": "urn:oid:2.16.578.1.12.4.1.4.4",
          "value": "222200063"
        },
        "display": "Tandberg, Gard"
      },
      "organization": {
        "identifier": {
          "system": "urn:oid:2.16.578.1.12.4.1.4.101",
          "value": "986664203"
        },
        "display": "Sjøsiden Legesenter"
      },
      "code": [
        {
          "coding": [
            {
              "system": "http://nhn.no/kj/fhir/CodeSystem/CategoriesOfHealthProfessionals",
              "code": "LE",
              "display": "Lege"
            }
          ]
        }
      ]
    }
  ],
  "extension": [
    {
      "url": "http://nhn.no/kj/fhir/StructureDefinition/KjSourceOfInformation",
      "valueCoding": {
        "system": "http://nhn.no/kj/fhir/CodeSystem/SourceOfInformation",
        "code": "7",
        "display": "Opplyst av ansvarlig behandler"
      }
    }
  ],
  "clinicalStatus": {
    "coding": [
      {
        "system": "http://terminology.hl7.org/CodeSystem/condition-clinical",
        "code": "active",
        "display": "Active"
      }
    ]
  },
  "verificationStatus": {
    "coding": [
      {
        "system": "http://terminology.hl7.org/CodeSystem/condition-ver-status",
        "code": "confirmed",
        "display": "Confirmed"
      }
    ]
  },
  "category": [
    {
      "coding": [
        {
          "system": "http://nhn.no/kj/fhir/CodeSystem/SubcategoriesOfCriticalInformation",
          "code": "7",
          "display": "Implantat"
        }
      ]
    }
  ],
  "code": {
    "coding": [
      {
        "system": "http://nhn.no/kj/fhir/CodeSystem/ImplantsAndOtherForeignBodies",
        "code": "20",
        "display": "Transplantert nyre"
      }
    ],
    "text": "En spesifikasjon."
  },
  "subject": {
    "reference": "Patient/13116900216"
  },
  "onsetDateTime": "2017-03-14T00:00:00+01:00",
  "recordedDate": "1961-01-08T02:00:00+02:00",
  "recorder": {
    "reference": "#recorderRef"
  },
  "note": [
    {
      "text": "En kommentar."
    }
  ]
}